Kasalahan | Alesan | Manifestasi | Solusi |
Teu bisa muka | 1. The klep inlet nyaeta unopen | Solenoid coil berpungsi tapi teu aya aliran cai | Buka klep inlet |
2. controller ngabogaan sesar paréntah | The coil solenoid nyaeta unworking, sistem multiline bisa muka klep ku ngagunakeun kontak test | Pariksa setelan prosedural controller urang | |
3. Sirkuit kontrol rusak | Layar controller nembongkeun pesen warning;The coil solenoid nyaeta unworking;klep nu jalan normal mun anjeun loosen assembly solenoid sacara manual | Anggo multimeter pikeun pariksa naha garis kontrol mangrupikeun sirkuit pondok atanapi sirkuit kabuka sareng perbaikan | |
4. Cecekelan aliran nyaeta unopen | Layar controller nembongkeun klep dibuka;The solenoid coil berpungsi;Teu bisa muka klep sanajan anjeun loosen assembly solenoid sacara manual | Pulas gagang aliran ka posisi anu cocog | |
5. The solenoid coil ngarecahna | Layar controller nembongkeun pesen warning;The coil solenoid nyaeta unworking;klep nu jalan normal mun anjeun loosen assembly solenoid sacara manual;Garis kontrol diuji sacara normal | Ngaganti coil solenoid anyar | |
6. Pipa dicolokkeun | Layar controller nembongkeun klep dibuka;The solenoid coil berpungsi;Teu bisa muka klep sanajan nyaluyukeun cecekelan aliran atawa loosening assembly solenoid sacara manual | Ngabersihan rereged dina pipa | |
7. Arah masang salah | Theklep solenoidditutup nalika controller dihurungkeun, jeungklep solenoidkabuka atanapi aya kalana kabuka nalika controller pareum | Pamasangan ulang | |
Teu bisa nutup | 1. The coil solenoid ieu loosened | The solenoid coil berpungsi;Panyambung coil solenoid geus overflowed | Tighten up coil solenoid jeung ngaganti segel colokan |
2. Pipa dicolok atanapi pegat | controller nu teu bisa nutup;Tapi bisa nutup ku ngagunakeun cecekelan aliran | Ngabersihan rereged dina pipa | |
3. Cecekelan aliran twisted ka maksimum | Controller bisa nutup ku cara ngurangan cecekelan aliran appropriately | Pulas cecekelan aliran ka posisi anu pas | |
4. diafragma rusak | klep teu bisa nutup sanajan twisting cecekelan aliran ka minimum | Ganti diafragma | |
5. Kotoran aya di handapeun diafragma | klep teu bisa nutup sanajan twisting cecekelan aliran ka minimum | Buka klep sareng bersihkeun najis | |
6. Arah masang salah | Theklep solenoidditutup nalika controller dihurungkeun, sareng klep solenoid kabuka atanapi aya kalana kabuka nalika controller pareum | Pamasangan ulang |
waktos pos: Jan-08-2024